Pairs well with

LiFePO4 UPS

Reliable backup power for connected equipment

GoldenMate combines 1000 VA / 800 W capacity, pure sine wave output, eight outlets and a long-life LiFePO4 battery in one line-interactive UPS. It is designed for home offices, networking, security systems and other compatible connected equipment.

1000VA/800W GoldenMate LiFePO4 UPS

Everyday continuity

Protection that stays ready

Power backup for connected devices — 1000VA/800W LiFePO4 UPS

Keep home-office computers, networking equipment, security systems and other connected devices operating through short outages, with time to save work and shut down safely.

Long-life LiFePO4 backup — 1000VA/800W LiFePO4 UPS

Lower-maintenance design

Long-life LiFePO4 backup

LiFePO4 chemistry is engineered for long service life and reduced maintenance compared with traditional lead-acid UPS batteries.

Protection for work and data — 1000VA/800W LiFePO4 UPS

Clean, dependable power

Protection for work and data

Pure sine wave output and automatic battery transfer help protect sensitive equipment from outages and unstable utility power.

Runtime for the moments that matter

LiFePO4 battery cell array concept Up to 5000+ Life Cycles

Protection that fits the way you work

Home office UPS application

Home office

Protect computers, displays and essential work equipment.

Network and Wi-Fi UPS application

Network and Wi-Fi

Keep routers, modems and network-attached devices available during brief outages.

Security systems UPS application

Security systems

Support cameras, recorders and security hubs when utility power is interrupted.

Gaming and entertainment UPS application

Gaming and entertainment

Provide clean backup power for consoles, displays and connected entertainment equipment.

Engineered for dependable performance

Power & Output

1000 VA / 800 W; line-interactive topology; pure sine wave output.

Battery & Runtime

LiFePO4 battery; 230.4 Wh; up to 30 minutes at a 400 W reference load; recommended load 480–560 W; rated for 3000+ cycles.

Outlets & Transfer

Eight NEMA 5-15 outlets with a transfer time of 20 milliseconds or less.

Protection & Power Quality

250 V~, 15 A input protection; output THD below 5%; 90–140 V input range; 120 V output.

Build & Cooling

Desktop enclosure, 330 × 250 × 105 mm, 5.6 kg, fan cooling, and noise of 40 dB or less at 1 metre.

Operating Conditions

Designed for 0–40 °C operation and 20–90% RH non-condensing humidity.

Technical specifications

Product

Model number
UPS1000VA Pro/800W

Power

Apparent power
1000 VA
Active power
800 W

Physical

Form factor
Desktop
Dimensions (L × W × H)
330 × 250 × 105 mm
Net weight
5.6 kg
Color
Black / White

Input

Input voltage range
90–140 (±5) V
Input frequency
50/60 ±3 Hz
Input protection
250V~, 15A protector

Output

Output voltage
120 ±10% V
Output frequency
60 ±3 Hz
Output waveform
Pure Sine Wave
Transfer time
≤20 ms
Output THD
<5 %
Outlet / plug type
NEMA 5-15
Total outlets
8

Runtime

Reference load
400 W
Backup time
≤30 min
Recommended load range
480–560 W

Built-in battery

Battery chemistry
LiFePO4
Battery nominal voltage
25.6 V
Battery capacity
9 Ah
Battery energy
230.4 Wh
Recharge time
≤10 h
Cycle life
3000+ cycles

Environment

Noise
≤40 @1m dB
Cooling
Fan
Operating temperature
0–40 °C
Storage temperature
-15–40 °C
Operating humidity
20–90, non-condensing %RH

Frequently asked questions

Will this UPS provide continuous power during an outage?

It automatically switches to battery power when utility power fails. Its specified transfer time is 20 milliseconds or less, so most compatible computers and networking devices continue operating without interruption.

What does the LCD display show?

The display shows input and output voltage and remaining battery capacity. Display behaviour can vary between utility and battery operating modes.

How long will it run after the power goes out?

Runtime depends on connected load. Under the standard reference condition, this model provides up to 30 minutes at a 400 W load and 25 °C. Actual runtime varies with load, temperature and battery condition.

Can the audible alarm be silenced?

The UPS provides audible operating and low-battery alerts. Follow the product instructions for the available alarm-silence control and status indications.

Is the built-in battery user-replaceable?

The battery is built in and is not intended for user replacement. Contact GoldenMate support before attempting any battery service.