Pairs well with

Keep the working side of the office moving

A battery designed for years of backup events - 1500VA/1000W LiFePO4 UPS 8 Outlets (296Wh) AVR

A battery designed for years of backup events

LiFePO4 chemistry is made for repeated cycling, helping reduce the battery-replacement routine of a conventional office UPS.

Keep the working side of the office together - 1500VA/1000W LiFePO4 UPS 8 Outlets (296Wh) AVR

Keep the working side of the office together

Eight outlets plus USB-A and USB-C bring the computer, display, printer and small accessories onto one protected source.

Switch to battery before momentum is lost - 1500VA/1000W LiFePO4 UPS 8 Outlets (296Wh) AVR

Switch to battery before momentum is lost

A fast 4 to 6 ms transfer helps active work and connected equipment continue through a brief utility outage.

Technical specifications

Product

Model number
UPS-1500VA-10BKD01
UPS topology
Line-interactive / AVR

Power

Apparent power
1500 VA
Active power
1000 W

Physical

Form factor
Desktop
Dimensions (D × W × H)
425 × 160 × 300 mm
Net weight
15 kg
Color
White / Gray

Input

Input voltage range
90–140 V
Input frequency
50/60 ±3 Hz
Input protection
125/250V~, 15A breaker

Output

Output voltage
120 ±10% V
Output frequency
50/60 ±3 Hz
Output waveform
Pure Sine Wave
Transfer time
4–6 ms
Output THD
<5 %
Outlet / plug type
NEMA 5-15
Total outlets
8
USB / Type-C output
USB-A + USB-C, 5V/2A, 10W total

Runtime

Reference load
600 W
Backup time
≤30 min
Recommended load range
600–700 W

Built-in battery

Battery chemistry
LiFePO4
Battery nominal voltage
51.2 V
Battery capacity
5.8 Ah
Battery energy
296.96 Wh
Recharge time
4 h
Cycle life
3000+ cycles

Environment

Noise
≤50 @1m dB
Cooling
Fan
Operating temperature
0–40 °C
Storage temperature
-15–40 °C
Operating humidity
20–90, non-condensing %RH

Frequently asked questions

How long will it run after the power goes out?

Under the published reference condition, this model provides up to 30 minutes at a 600 W reference load. Actual runtime varies with connected load, temperature and battery condition.

What output waveform and transfer time does it use?

The UPS uses Pure Sine Wave output with a specified transfer time of ≤10 ms. Compatibility still depends on the connected equipment and its power requirements.

How long does the built-in battery take to recharge?

The published recharge time is ≤4 hours. Recharge time can vary with battery state, load and operating conditions; recharge the unit promptly after a low-battery event.

What outlets or communication interfaces are included?

8 outlets plus USB-A and USB-C (5 V/2 A, 10 W total).

What load and maintenance limits should I follow?

Do not exceed this model’s rated 1200 W output. Keep the UPS in a dry, ventilated indoor location, and stop use if it shows abnormal heat, odor, deformation or fault indications. Battery maintenance or replacement should be handled by qualified personnel.