Pairs well with

Steady power for a more demanding workstation

Extra output for a demanding workstation - 1500VA/1200W LiFePO4 UPS 8 Outlets (296Wh) AVR

Extra output for a demanding workstation

Support a higher-draw desktop setup, networking equipment and office peripherals from one compact backup system.

Keep short outages from breaking the flow - 1500VA/1200W LiFePO4 UPS 8 Outlets (296Wh) AVR

Keep short outages from breaking the flow

Fast transfer to battery helps protect active work, calls and network sessions when utility power disappears for a moment.

Correct unstable power before using the battery - 1500VA/1200W LiFePO4 UPS 8 Outlets (296Wh) AVR

Correct unstable power before using the battery

Automatic voltage regulation handles common utility fluctuations, while pure sine wave output suits sensitive electronics.

Technical specifications

Product

Model number
UPS1500VA/1200W
UPS topology
Line-interactive / AVR

Power

Apparent power
1500 VA
Active power
1200 W

Physical

Form factor
Desktop
Dimensions (L × W × H)
425 × 300 × 160 mm
Net weight
15 kg

Input

Input voltage range
90–140 (±5) V
Input frequency
50/60 ±3 Hz
Input protection
120V~, 20A protector

Output

Output voltage
120 ±10% V
Output frequency
60 ±3 Hz
Output waveform
Pure Sine Wave
Transfer time
≤10 ms
Output THD
<5 %
Outlet / plug type
NEMA 5-15
Total outlets
8
USB / Type-C output
USB-A + USB-C, 5V/2A, 10W total

Runtime

Reference load
600 W
Backup time
≤30 min
Recommended load range
720–840 W

Built-in battery

Battery chemistry
LiFePO4
Battery nominal voltage
51.2 V
Battery capacity
5.8 Ah
Battery energy
296.96 Wh
Recharge time
≤4 h
Cycle life
3000+ cycles

Environment

Noise
≤45 dB
Cooling
Fan
Operating temperature
0–40 °C
Storage temperature
-15–40 °C
Operating humidity
20–90, non-condensing %RH

Frequently asked questions

How long will it run after the power goes out?

Under the published reference condition, this model provides up to 30 minutes at a 600 W reference load. Actual runtime varies with connected load, temperature and battery condition.

What output waveform and transfer time does it use?

The UPS uses Pure Sine Wave output with a specified transfer time of ≤10 ms. Compatibility still depends on the connected equipment and its power requirements.

How long does the built-in battery take to recharge?

The published recharge time is ≤4 hours. Recharge time can vary with battery state, load and operating conditions; recharge the unit promptly after a low-battery event.

What outlets or communication interfaces are included?

8 outlets plus USB-A and USB-C (5 V/2 A, 10 W total).

What load and maintenance limits should I follow?

Do not exceed this model’s rated 1200 W output. Keep the UPS in a dry, ventilated indoor location, and stop use if it shows abnormal heat, odor, deformation or fault indications. Battery maintenance or replacement should be handled by qualified personnel.