Pairs well with

LiFePO4 UPS

Reliable backup for NAS and network continuity

Protect compatible NAS systems, routers, switches and home-office equipment with 1000 VA / 800 W pure sine wave backup power, eight outlets and a 230.4 Wh LiFePO4 battery.

1000VA/800W GoldenMate LiFePO4 UPS

Storage protection

Protection that stays ready

Power backup for connected devices — 1000VA/800W LiFePO4 UPS

Help keep compatible storage, networking and workstation equipment running through outages and unstable utility power with pure sine wave output.

Long-life LiFePO4 backup — 1000VA/800W LiFePO4 UPS

NAS-ready outlets

Keep storage and network gear on one UPS

Connect a NAS, router, switch, monitor and other essential devices through eight NEMA 5-15 outlets, while keeping total demand within the model's rated output.

Protection for work and data — 1000VA/800W LiFePO4 UPS

Status at a glance

Check UPS status beside your network stack

Check input, output, operating mode and battery condition directly on the LCD, making it easier to respond during an outage or troubleshooting session.

Runtime for the moments that matter

UP to 5000 cycles - 1000VA/800W LiFePO4 UPS runtime visual Up to 5000+ Life Cycles

Protection that fits the way you work

Home office UPS application

Home office

Protect computers, displays and essential work equipment.

Network and Wi-Fi UPS application

Network and Wi-Fi

Keep routers, modems and network-attached devices available during brief outages.

Security systems UPS application

Security systems

Support cameras, recorders and security hubs when utility power is interrupted.

Gaming and entertainment UPS application

Gaming and entertainment

Provide clean backup power for consoles, displays and connected entertainment equipment.

Engineered for dependable performance

Power & Output

1000 VA / 800 W; line-interactive topology; pure sine wave output.

Battery & Runtime

LiFePO4 battery; 230.4 Wh; up to 30 minutes at a 400 W reference load; recommended load 480–560 W; rated for 3000+ cycles.

Outlets & Transfer

Eight NEMA 5-15 outlets with a transfer time of 20 milliseconds or less.

Protection & Power Quality

250 V~, 15 A input protection; output THD below 5%; 90–140 V input range; 120 V output.

Build & Cooling

Desktop enclosure, 330 × 250 × 105 mm, 5.6 kg, fan cooling, and noise of 40 dB or less at 1 metre.

Operating Conditions

Designed for 0–40 °C operation and 20–90% RH non-condensing humidity.

Technical specifications

Product

Model number
UPS1000VA Pro/800W NAS

Power

Apparent power
1000 VA
Active power
800 W

Physical

Form factor
Desktop
Dimensions (L × W × H)
330 × 250 × 105 mm
Net weight
5.6 kg
Color
Black / White

Input

Input voltage range
90–140 (±5) V
Input frequency
50/60 ±3 Hz
Input protection
250V~, 15A protector

Output

Output voltage
120 ±10% V
Output frequency
60 ±3 Hz
Output waveform
Pure Sine Wave
Transfer time
≤20 ms
Output THD
<5 %
Outlet / plug type
NEMA 5-15
Total outlets
8

Runtime

Reference load
400 W
Backup time
≤30 min
Recommended load range
480–560 W

Built-in battery

Battery chemistry
LiFePO4
Battery nominal voltage
25.6 V
Battery capacity
9 Ah
Battery energy
230.4 Wh
Recharge time
≤10 h
Cycle life
3000+ cycles

Environment

Noise
≤40 @1m dB
Cooling
Fan
Operating temperature
0–40 °C
Storage temperature
-15–40 °C
Operating humidity
20–90, non-condensing %RH

Frequently asked questions

How long will it run after the power goes out?

Under the published reference condition, this model provides up to 30 minutes at a 400 W reference load. Actual runtime varies with connected load, temperature and battery condition.

What output waveform and transfer time does it use?

The UPS uses Pure Sine Wave output with a specified transfer time of ≤20 ms. Compatibility still depends on the connected equipment and its power requirements.

How long does the built-in battery take to recharge?

The published recharge time is ≤10 hours. Recharge time can vary with battery state, load and operating conditions; recharge the unit promptly after a low-battery event.

What outlets or communication interfaces are included?

8 NEMA 5-15 outlets and a NAS/PC communication interface. Use only the supplied or specified cable and follow the product instructions for any communication or NAS shutdown integration.

What load and maintenance limits should I follow?

Do not exceed this model’s rated 800 W output. Keep the UPS in a dry, ventilated indoor location, and stop use if it shows abnormal heat, odor, deformation or fault indications. Battery maintenance or replacement should be handled by qualified personnel.