Pairs well with

High-output protection, mounted out of the way

Move serious backup power off the floor - 1500VA/1000W LiFePO4 UPS Wall-Mount

Move serious backup power off the floor

The wall-mounted format opens space around the desk while keeping the UPS close to the workstation and network gear it protects.

Bring a fuller workstation onto one source - 1500VA/1000W LiFePO4 UPS Wall-Mount

Bring a fuller workstation onto one source

Eight AC outlets plus USB-A and USB-C support computers, displays, networking equipment and personal devices from one installation.

Check power status from across the desk - 1500VA/1000W LiFePO4 UPS Wall-Mount

Check power status from across the desk

The color display keeps input, output and battery condition visible without moving the wall-mounted unit or opening software.

Technical specifications

Product

Model number
UPS-1500VA-10BKW01
UPS topology
Standby

Power

Apparent power
1500 VA
Active power
1000 W

Physical

Form factor
Wall-mount
Dimensions (L × W × H)
330 × 250 × 90 mm
Net weight
6.3 kg
Color
Gray

Input

Input voltage range
90–140 V
Input frequency
50/60 ±3 Hz
Input protection
125/250V~, 15A breaker

Output

Output voltage
120 ±10% V
Output frequency
50/60 ±3 Hz
Output waveform
Pure Sine Wave
Transfer time
≤10 ms
Output THD
<5 %
Outlet / plug type
NEMA 5-15
Total outlets
8
USB / Type-C output
USB-A + USB-C, 5V/2A, 10W total

Runtime

Reference load
500 W
Backup time
~24 min
Recommended load range
600–700 W

Built-in battery

Battery chemistry
LiFePO4
Battery nominal voltage
25.6 V
Battery capacity
9 Ah
Battery energy
230.4 Wh
Recharge time
~10 h
Cycle life
3000+ cycles

Environment

Noise
≤50 @1m dB
Cooling
Fan
Operating temperature
0–40 °C
Storage temperature
-15–40 °C
Operating humidity
20–90, non-condensing %RH

Frequently asked questions

How long will it run after the power goes out?

Under the published reference condition, this model provides about 24 minutes at a 500 W reference load. Actual runtime varies with connected load, temperature and battery condition.

What output waveform and transfer time does it use?

The UPS uses Pure Sine Wave output with a specified transfer time of ≤10 ms. Compatibility still depends on the connected equipment and its power requirements.

How long does the built-in battery take to recharge?

The published recharge time is about 10 hours. Recharge time can vary with battery state, load and operating conditions; recharge the unit promptly after a low-battery event.

What outlets or communication interfaces are included?

8 NEMA 5-15 outlets plus USB-A and USB-C (5 V/2 A, 10 W total).

What load and maintenance limits should I follow?

Do not exceed this model’s rated 1000 W output. Keep the UPS in a dry, ventilated indoor location, and stop use if it shows abnormal heat, odor, deformation or fault indications. Battery maintenance or replacement should be handled by qualified personnel.