Pairs well with

More power for connected workspaces

Support higher-demand desktop, networking and office setups with 1500 VA / 1200 W pure sine wave AVR backup, eight outlets and a 296.96 Wh LiFePO4 battery.

GoldenMate LiFePO4 UPS protecting a connected workspace

Protection that stays ready

AVR LiFePO4 UPS protecting office equipment and connected electronics

LiFePO4 chemistry is built for repeated cycling, helping reduce the battery-replacement routine of a conventional office UPS.

AVR UPS rear panel with eight protected outlets and USB charging ports

Keep the working side of the office together

Eight outlets plus USB-A and USB-C bring the computer, display, networking gear and small accessories onto one protected source.

AVR UPS LCD showing input output load and battery status

Correct unstable power before using the battery

Automatic voltage regulation handles common utility fluctuations, while the LCD keeps input, output and battery status visible at a glance.

Runtime for the moments that matter

UP to 5000 cycles - 1000VA/800W LiFePO4 UPS runtime visual Up to 5000+ Life Cycles

Protection that fits the way you work

AVR UPS supporting a home office setup

Home office

Protect computers, displays and essential work equipment.

AVR UPS supporting network and Wi-Fi equipment

Network and Wi-Fi

Keep routers, modems and network-attached devices available during brief outages.

AVR UPS supporting security systems

Security systems

Support cameras, recorders and security hubs when utility power is interrupted.

AVR UPS supporting gaming and entertainment equipment

Gaming and entertainment

Provide clean backup power for consoles, displays and connected entertainment equipment.

Engineered for dependable performance

Power & Output

1500 VA / 1200 W; line-interactive AVR topology; pure sine wave output.

Battery & Runtime

LiFePO4 battery; 296.96 Wh; up to 30 minutes at a 600 W reference load; recommended load 720–840 W; recharge time of 4 hours or less.

Outlets & Transfer

Eight NEMA 5-15 outlets with a transfer time of 10 milliseconds or less; USB-A and USB-C output rated at 10 W total.

Protection & Power Quality

120 V~, 20 A input protection; output THD below 5%; 90–140 V input range; 120 V ±10% output.

Build & Cooling

Desktop enclosure, 425 × 300 × 160 mm, 15 kg, fan cooling, and noise of 45 dB or less.

Operating Conditions

Designed for 0–40 °C operation and 20–90% RH non-condensing humidity.

Technical specifications

Product

Model number
UPS1500VA/1200W
UPS topology
Line-interactive / AVR

Power

Apparent power
1500 VA
Active power
1200 W

Physical

Form factor
Desktop
Dimensions (L × W × H)
425 × 300 × 160 mm
Net weight
15 kg

Input

Input voltage range
90–140 (±5) V
Input frequency
50/60 ±3 Hz
Input protection
120V~, 20A protector

Output

Output voltage
120 ±10% V
Output frequency
60 ±3 Hz
Output waveform
Pure Sine Wave
Transfer time
≤10 ms
Output THD
<5 %
Outlet / plug type
NEMA 5-15
Total outlets
8
USB / Type-C output
USB-A + USB-C, 5V/2A, 10W total

Runtime

Reference load
600 W
Backup time
≤30 min
Recommended load range
720–840 W

Built-in battery

Battery chemistry
LiFePO4
Battery nominal voltage
51.2 V
Battery capacity
5.8 Ah
Battery energy
296.96 Wh
Recharge time
≤4 h
Cycle life
3000+ cycles

Environment

Noise
≤45 dB
Cooling
Fan
Operating temperature
0–40 °C
Storage temperature
-15–40 °C
Operating humidity
20–90, non-condensing %RH

Frequently asked questions

How long will it run after the power goes out?

Under the published reference condition, this model provides up to 30 minutes at a 600 W reference load. Actual runtime varies with connected load, temperature and battery condition.

What output waveform and transfer time does it use?

The UPS uses Pure Sine Wave output with a specified transfer time of ≤10 ms. Compatibility still depends on the connected equipment and its power requirements.

How long does the built-in battery take to recharge?

The published recharge time is ≤4 hours. Recharge time can vary with battery state, load and operating conditions; recharge the unit promptly after a low-battery event.

What outlets or communication interfaces are included?

8 outlets plus USB-A and USB-C (5 V/2 A, 10 W total).

What load and maintenance limits should I follow?

Do not exceed this model’s rated 1200 W output. Keep the UPS in a dry, ventilated indoor location, and stop use if it shows abnormal heat, odor, deformation or fault indications. Battery maintenance or replacement should be handled by qualified personnel.