Pairs well with

More headroom around connected storage

Add headroom around the storage system - 1000VA/800W LiFePO4 UPS Pro 8 Outlets (230.4Wh) NAS

Add headroom around the storage system

The 800 W design can keep the NAS, network hardware and a more capable workstation on the same protected power path.

See what the UPS is doing at a glance - 1000VA/800W LiFePO4 UPS Pro 8 Outlets (230.4Wh) NAS

See what the UPS is doing at a glance

The front display makes input, output and remaining battery state easy to check during a transfer or troubleshooting session.

Manage heat during sustained office use - 1000VA/800W LiFePO4 UPS Pro 8 Outlets (230.4Wh) NAS

Manage heat during sustained office use

Active airflow helps the higher-output UPS control internal heat while it supports an always-on network and workstation.

Technical specifications

Product

Model number
UPS1000VA Pro/800W NAS

Power

Apparent power
1000 VA
Active power
800 W

Physical

Form factor
Desktop
Dimensions (L × W × H)
330 × 250 × 105 mm
Net weight
5.6 kg
Color
Black / White

Input

Input voltage range
90–140 (±5) V
Input frequency
50/60 ±3 Hz
Input protection
250V~, 15A protector

Output

Output voltage
120 ±10% V
Output frequency
60 ±3 Hz
Output waveform
Pure Sine Wave
Transfer time
≤20 ms
Output THD
<5 %
Outlet / plug type
NEMA 5-15
Total outlets
8

Runtime

Reference load
400 W
Backup time
≤30 min
Recommended load range
480–560 W

Built-in battery

Battery chemistry
LiFePO4
Battery nominal voltage
25.6 V
Battery capacity
9 Ah
Battery energy
230.4 Wh
Recharge time
≤10 h
Cycle life
3000+ cycles

Environment

Noise
≤40 @1m dB
Cooling
Fan
Operating temperature
0–40 °C
Storage temperature
-15–40 °C
Operating humidity
20–90, non-condensing %RH

Frequently asked questions

How long will it run after the power goes out?

Under the published reference condition, this model provides up to 30 minutes at a 400 W reference load. Actual runtime varies with connected load, temperature and battery condition.

What output waveform and transfer time does it use?

The UPS uses Pure Sine Wave output with a specified transfer time of ≤20 ms. Compatibility still depends on the connected equipment and its power requirements.

How long does the built-in battery take to recharge?

The published recharge time is ≤10 hours. Recharge time can vary with battery state, load and operating conditions; recharge the unit promptly after a low-battery event.

What outlets or communication interfaces are included?

8 NEMA 5-15 outlets and a NAS/PC communication interface. Use only the supplied or specified cable and follow the product instructions for any communication or NAS shutdown integration.

What load and maintenance limits should I follow?

Do not exceed this model’s rated 800 W output. Keep the UPS in a dry, ventilated indoor location, and stop use if it shows abnormal heat, odor, deformation or fault indications. Battery maintenance or replacement should be handled by qualified personnel.